Ultracentrifuge is used for centrifugation of subcellular particles, virus isolations, and high purity plasmid DNA.
Proper citation: Beckman Coulter L-90K Ultracentrifuge (RRID:SCR_019651) Copy
https://www.brookhaveninstruments.com/product/bi-200sm-research-goniometer/
Goniometer that is used for macro molecular studies and submicron particle sizing with static and dynamic light scattering. It can be used with neutral density filters, polarizer, analyzer, and reference detector.
Proper citation: Brookhaven Instruments BI-200SM Research Goniometer (RRID:SCR_019754) Copy
https://www.gmi-inc.com/product/packard-cobra-gamma-counter-series/
Gamma counter available in single, five, or ten detector configurations. Can count RIA tubes, 16x100mm and variety of smaller micro tubes using available adapter.This instrument has dot Matrix Printer, tube racks, and protocol ID tags.Single detector model is available in 2 inch or 3 inch crystal configurations for research grade capabilities.
Proper citation: Packard Cobra 5000 Gamma Counter (RRID:SCR_018609) Copy
Dual channel fluorimeter for fluorescence measurements when calibrated with known concentration to measure compounds at low concentration with low assay volume.
Proper citation: Promega TBS-380 Fluorimeter (RRID:SCR_018615) Copy
Microplate luminometer that features two optional injectors and reads both glow- and flash-luminescent reactions in 96-well plates. The sensitivity and range enable a wide range of luminescent assays, including Promega bioluminescent reporter, cell-based and biochemical assays., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Promega GloMax 96 Microplate Luminometer (RRID:SCR_018614) Copy
Sequencing and quantification platform for epigenetics, mutation gene expression analysis, and microbial identification and resistance typing. With its 96-well format, automatic base-calling function, and dedicated software solutions for methylation analysis and assay design.
Proper citation: Qiagen PyroMark Q96 System (RRID:SCR_018617) Copy
http://tools.thermofisher.com/content/sfs/brochures/geneatlas_system_brochure.pdf
System for processing Affymetrix microarrays. Microarray analysis system. Includes array strip and hybridization assembly, Fluidics station, Imaging station.
Proper citation: GeneAtlas System (RRID:SCR_018715) Copy
https://www.thermofisher.com/order/catalog/product/ND-8000-GL
Microvolume UV Vis spectrophotometer for nucleic acid and protein quantification that can measure multiple samples using 1 to 2 uL of samples. Can analyze spectrum of 220nm to 750nm and measure 96 samples in less than six minutes. Can measure multiple samples in one measurement cycle, up to eight samples at one time. Has single sample mode. Can analyze the full spectrum from 220 to 750nm and calculates sample purity ratios 260/280.
Proper citation: Thermo Scientific NanoDrop 8000 Spectrophotometer (RRID:SCR_018600) Copy
https://www.nikonmetrology.com/en-us/product/az100-multizoom
Nikon Instruments AZ100 C1si is macro confocal microscope system combining stereo and compound microscopes into single hybrid imaging system for dynamic imaging of single cells or whole specimens.System covers range of magnifications from 5x to 400x. Has triple nosepiece that can switch magnifications. AZ100 C1si boasts simultaneous 32 channel spectral image acquisition over spectral range of 320 nm in single scan. Simultaneous 32 channel acquisition at 10 nm, 5 nm or 2.5 nm bandwidths, all software controlled, is possible.
Proper citation: Nikon AZ100 Confocal Microscope (RRID:SCR_018603) Copy
https://www.marshallscientific.com/The-MJ-Research-PTC-100-Thermal-Cycler-p/mj-100.htm
Thermocycler that operates with 96 well and 60 well microplates. Has temperature configurations from 0 C to 105 C and pressure and height adjustment via thumbwheel. Comes with 14 pre-programmed protocols.
Proper citation: MJ Research PTC-100 PCR Thermocycler (RRID:SCR_018602) Copy
https://www.labx.com/product/waters-2695
High performance liquid chromatographic system with quaternary, low pressure mixing pump and inline vacuum degassing. It has wavelengths of 190 to 800 nm and flow rates from 50 uL per min to 5 mL per min with 2.1 mm ID columns and larger. Autosampler has maximum capacity of 120 vials (12x32, 2 mL) with programmable temperature control from 4 to 40C. Heated column compartment provides temperatures from 5 degrees above ambient to 65C.
Proper citation: Waters 2695 HPLC System (RRID:SCR_018649) Copy
https://www.mpbio.com/fastprep-24-5g-instrument
Sample disruption instrument that can homogenize, grind, or lyse biological samples. Samples are added to individual lysing matrix tubes and shaken in tridimensional motion.
Proper citation: MP Biochemicals FastPrep24 Sample Preparation (RRID:SCR_018599) Copy
http://labx.com/product/stratagene-stratalinker-1800
UV crosslinker designed to crosslink DNA or RNA to nylon, nitrocellulose, or nylon reinforced nitrocellulose membranes in 25 to 50 seconds. It is equipped with internal photodetector to compensate for aging ultraviolet bulbs.
Proper citation: Stratagene 1800 UV Crosslinker (RRID:SCR_018631) Copy
https://www.labx.com/product/sciex-4000-qtrap-
Hybrid triple quadrupole linear ion trap mass spectrometer for drug discovery and development, metabolite identification, contaminant testing, proteomic applications, post translationally modified proteins discovery, protein identification, and biomarker validation.
Proper citation: SCIEX 4000 QTRAP Mass Spectrometer (RRID:SCR_018630) Copy
https://www.tainstruments.com/3200-system/
Mechanical testing apparatus with 225 N or 450 N maximum force and range of static to 300 Hz frequency response. Tests include torsion testing, creep under dynamic loading, special environment hot cold chambers, biomedical research, and engineered materials test applications..
Proper citation: TA Instruments Electroforce 3200 Mechanical Testing Apparatus (RRID:SCR_018637) Copy
https://diagnostics.roche.com/global/en/products/instruments/discovery-xt-research-platform.html
Immunohistochemistry processor that can be used for immunohistochemistry and in situ hybridization slide preparation and processing.
Proper citation: Ventana Discovery XT Immunohistochemistry Processor (RRID:SCR_018643) Copy
Automated wide range incubator used to minimize plate movement, receive samples, store plates, and track plates.Temperature range is from 10 to 50 degrees Celsius with humidity level of up to 95 rH.
Proper citation: Thermo Scientific Cytomat 6001 Automated Wide Range Incubator (RRID:SCR_018646) Copy
Femto Pulse System separates large molecular weight DNA fragments and detects nucleic acids into femtogram range.Fragment analyzer that provides pulsed field power supply which allows large molecular weight DNA fragments to be separated and nucleic acids detected into femtogram range. Ability to separate high molecular weight DNA up to 165 kb and detect nucleic acids down to 50 fg per uL input concentration makes system ideal for long-read NGS QC, gDNA, small RNA, or cfDNA analysis from low concentration samples.
Proper citation: Agilent Femto Pulse System (RRID:SCR_018058) Copy
https://www.thermofisher.com/order/catalog/product/3730S#/3730S
Medium to high throughput genetic analyzer that performs DNA fragment analysis applications such as microsatellites, AFLP, SNP analysis, mutation detection and traditional DNA sequencing. Upgradeable to 96 capillaries.
Proper citation: Applied Biosystems 3730 Genetic Analyzer (RRID:SCR_018052) Copy
Refridgerated centrifuge with 18 place capacity rotor that accomdates low to medium capacity in 1.5 or 2.0 mL tubes and Microtainer. Speed allows for standard molecular biology applications. Compact size and quiet operation.
Proper citation: Eppendorf 5418 R Centrifuge (RRID:SCR_018050) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.