https://www.htximaging.com/htx-m5-sprayer
Sprayer builds on capabilities of HTX TM-Sprayer providing innovative M5 chassis, high velocity stage and heated sample holder drawer. Sample plate holder is mounted on drawer mechanism to allow easy loading of samples, better protection of user and better alignment of various plate types. New High-Velocity XY stage allows nozzle displacement speed of up to 5,600mm/min and expands process range. Super dry spray can be achieved at high flow rates of solvent further improving instrument performance. E/Z trough gutter design improves chemical containement and is easy to remove and clean. Bulkhead connectors are directly mounted on it to also allow easy access to in line filter.
Proper citation: HTX M5 Sprayer (RRID:SCR_023733) Copy
https://andor.oxinst.cn/products/scmos-camera-series/zyla-4-2-scmos
Zyla 4.2 PLUS is the latest sCMOS technology advancement from Andor. At its heart, Zyla 4.2 PLUS benefits from latest generation sCMOS sensor technology, delivering a further 10 % boost in QE, resulting in an unprecedented 82% QEmax.
Proper citation: Andor Zyla 4.2 sCMOS (RRID:SCR_023610) Copy
Mass spectrometer designed for most difficult analytical challenges. Incorporates inventions in ion transmission and control, extended m/z range, and real-time decision making. System suited for proteomics, structural biology, small-molecule, and biopharmaceutical characterization experiments.
Proper citation: Thermo Scientific Orbitrap Eclipse Tribrid mass spectrometer (RRID:SCR_023618) Copy
Inverted microscope Axio Observer 3 for transmitted light brightfield LED and differential interference contrast. Used for demanding multimodal imaging.
Proper citation: Zeiss Axio Observer 3 (RRID:SCR_023693) Copy
https://industry.nikon.com/en-us/products/x-ray-ct/xt-h-225-xt-h-320/
Provides insight into the inside of components and specimens, allowing users to visualize, analyze and measure complex internal geometry as well as surfaces, all non-destructively. Versatile microfocus CT system for high resolution inspection in R&D and failure analysis of components ranging from tiny plastic connectors up to aluminum castings.
Proper citation: Nikon XT H 225 ST uCT system (RRID:SCR_023687) Copy
Pipet-Lite™ XLS+ manual single-channel pipette, 100-1000 μL, uses LTS™ LiteTouch™ tips. Accurate and precise, ergonomic, autoclavable liquid end, rugged and durable (L-1000XLS+)
Proper citation: Rainin Pipet-Lite LTS Pipette L-1000XLS+ (RRID:SCR_023894) Copy
Pipet-Lite™ XLS+ manual single-channel pipette, 20-200 μL, uses LTS™ LiteTouch™ tips. Accurate and precise, ergonomic, autoclavable liquid end, rugged and durable (L-200XLS+)
Proper citation: Rainin Pipet-Lite LTS Pipette L-200XLS+ (RRID:SCR_023892) Copy
https://www.hitachi-keu.com/en-gb/iv/hv-f203gvscl.html
High resolution 1/1.8" 3 CCD Progressive Scan Color Camera with 1600 x 1200 pixel (UXGA) that is installed in the ZEISS Axioscan Z1 slide scanner. Integrated functions include electronic shutter from 1/30s to 1/100000s, Long term Integration up to 4s, AGC, external Trigger, Auto Shading, 6 Colour Masking, Frame-On-Demand Function, White Balance, AGC, Black Level Adjustment and Partial Scan Function.
Proper citation: Hitachi 16-bit 3-CCD color camera HV-F203GV / HV-F203SCL (RRID:SCR_023888) Copy
https://www.sunchrom.de/en/products/maldi-ms-sample-preparation-2/suncollect-cf-spotter.html
CF-Spotter for MALDI-TOF microbial identification. Enables fast, efficient and reproducible sample preparation for MALDI-TOF microbial identification system and relieves your laboratory staff from tedious and time-consuming pipetting. Due to the non-contact application of the solutions, there is no carryover of the samples and the costs for consumables such as pipette tips are eliminated.
Proper citation: SunCollect CF Spotter (RRID:SCR_023906) Copy
https://www.sunchrom.de/en/products/maldi-ms-sample-preparation-2/sundigest.html
SunDigest incubation device provides fully software controlled and highly reproducible digestion process under standardized conditions. Feature includes Temperatures precisely adjustable between 4 °C and 50 °C; On-Tissue digestion process under optimal humidity; Preservation of spatial resolution; High performance digestion at 50 °C; Full digestion process control.Essential for reproducible results.
Proper citation: SunDigest Incubator (RRID:SCR_023905) Copy
Leica ST5010 Autostainer XL provides reproducible, consistent high quality staining, and increased workload throughput compared to manual staining.
Proper citation: Leica Autostainer ST5010 XL (RRID:SCR_023957) Copy
https://www.beckman.com/flow-cytometry/clinical-flow-cytometers/navios-ex
Designed specifically for clinical laboratory NAVIOS EX 10-color flow cytometer delivers performance with improved sample traceability and reporting functions. Navios EX has two optional ready-to-use IVD reagent systems, the Navios Tetra System for simultaneous identification and enumeration of T, B and NK lymphocytes and the ClearLLab 10C System – the first FDA cleared and CE marked integrated leukemia and lymphoma immunophenotyping system.
Proper citation: Beckman Coulter Navios EX flow cytometer (RRID:SCR_023797) Copy
https://mass-spec.stanford.edu/instruments
Agilent 6495C triple quadrupole LC/MS system increases capacity and sensitivity for targeted quantitation applications. Used to investigate more diverse and biologically relevant groups of targeted peptides, small molecules and metabolites in single experiment without compromising sensitivity, quantitative accuracy, or linearity.
Proper citation: Agilent 6495 Triple Quadrupole LC/MS (RRID:SCR_023937) Copy
https://www.ambulatory-monitoring.com/pvt-192-psychomotor-vigilance-monitor
System includes PVT-192 monitor and REACT software. Used for reaction time testing for long-term, large-scale testing of vigilance, effects of sleep deprivation, and drug effects. Used for PVT test wherever measures of performance or sleepiness effects are needed.
Proper citation: Psychomotor Vigilance Task system (RRID:SCR_024213) Copy
https://www.eneuro.org/content/10/8/ENEURO.0212-23.2023
Simple, lightweight, and low cost customizable multielectrode array for Local Field Potential recordings. Used to collect LFP data from different brain regions simultaneously in rats. Can be modified to record single unit and multiunit activity in addition to LFP activity using both wired and wireless neural data acquisition systems.
Proper citation: Customizable Multielectrode Array (RRID:SCR_024551) Copy
https://docplayer.net/37250096-Fei-philips-cm120-tem.html
Transmission electron microscope with maximum acceleration voltage of 120 kv.Microscope primarily used for sample screening.
Proper citation: Philips/FEI CM120 BioTwin Transmission Electron Microscope (RRID:SCR_024709) Copy
https://www.emerson.com/en-us/catalog/branson-sfx250
Branson Sonifier ultrasonic cell disruptor / homogenizers are versatile laboratory units suitable for broad range of liquid processing applications. Digital sonifier to disrupt cells, bacteria, spores, or tissue. Ideal for initiating and accelerating chemical, biochemical, and physical reactions, and for degassing liquids. Used to prepare emulsion to 0.01 micron, homogenize immiscible liquids, polymerize some materials, and depolymerize others.
Proper citation: Branson Digital Sonifier SFX250 (RRID:SCR_024710) Copy
https://precisionary.com/wp-content/uploads/2018/06/Compresstome-VF-700-0Z-User-Manual_FINAL.pdf
Vibrotome by Precisionary Instruments designed for cutting fixed tissue slices for histology studies. Offers two point stabilization of blade holder to eliminate unwanted chatter marks on surfaces of tissue slice. Fully automated to section fixed tissues with thickness range of 4 um to 2000 um with adjustable precision of 1 um.
Proper citation: Compresstome VF-700 (RRID:SCR_018409) Copy
https://www.olympus-lifescience.com/en/microscopes/virtual/vs120/
VS120 Virtual Slide Microscope. Part of slide loader system for manually loading standard slides by Olympus.
Proper citation: Olympus VS120 microscope (RRID:SCR_018411) Copy
https://glycocheck.com/health-score-technology/
Microvascular health measurement system that measures endothelial glycocalyx layer of vessels by MicroVascular Health Solutions. Software automatically identifies measurable micro vessels, below 30 µm thickness, during acquisition by contrast between RBC and background. After acquisition, software undergoes series of quality checks to measure vascular segments that are of good quality. Video microscope is placed under tongue, showing live movement of red blood cells as they travel through micro vessels.
Proper citation: GlycoCheck (RRID:SCR_018254) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.