Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
Pipet-Lite™ XLS+ manual single-channel pipette, 20-200 μL, uses LTS™ LiteTouch™ tips. Accurate and precise, ergonomic, autoclavable liquid end, rugged and durable (L-200XLS+)
Proper citation: Rainin Pipet-Lite LTS Pipette L-200XLS+ (RRID:SCR_023892) Copy
https://www.hitachi-keu.com/en-gb/iv/hv-f203gvscl.html
High resolution 1/1.8" 3 CCD Progressive Scan Color Camera with 1600 x 1200 pixel (UXGA) that is installed in the ZEISS Axioscan Z1 slide scanner. Integrated functions include electronic shutter from 1/30s to 1/100000s, Long term Integration up to 4s, AGC, external Trigger, Auto Shading, 6 Colour Masking, Frame-On-Demand Function, White Balance, AGC, Black Level Adjustment and Partial Scan Function.
Proper citation: Hitachi 16-bit 3-CCD color camera HV-F203GV / HV-F203SCL (RRID:SCR_023888) Copy
https://www.sunchrom.de/en/products/maldi-ms-sample-preparation-2/suncollect-cf-spotter.html
CF-Spotter for MALDI-TOF microbial identification. Enables fast, efficient and reproducible sample preparation for MALDI-TOF microbial identification system and relieves your laboratory staff from tedious and time-consuming pipetting. Due to the non-contact application of the solutions, there is no carryover of the samples and the costs for consumables such as pipette tips are eliminated.
Proper citation: SunCollect CF Spotter (RRID:SCR_023906) Copy
https://www.sunchrom.de/en/products/maldi-ms-sample-preparation-2/sundigest.html
SunDigest incubation device provides fully software controlled and highly reproducible digestion process under standardized conditions. Feature includes Temperatures precisely adjustable between 4 °C and 50 °C; On-Tissue digestion process under optimal humidity; Preservation of spatial resolution; High performance digestion at 50 °C; Full digestion process control.Essential for reproducible results.
Proper citation: SunDigest Incubator (RRID:SCR_023905) Copy
Leica ST5010 Autostainer XL provides reproducible, consistent high quality staining, and increased workload throughput compared to manual staining.
Proper citation: Leica Autostainer ST5010 XL (RRID:SCR_023957) Copy
https://www.beckman.com/flow-cytometry/clinical-flow-cytometers/navios-ex
Designed specifically for clinical laboratory NAVIOS EX 10-color flow cytometer delivers performance with improved sample traceability and reporting functions. Navios EX has two optional ready-to-use IVD reagent systems, the Navios Tetra System for simultaneous identification and enumeration of T, B and NK lymphocytes and the ClearLLab 10C System – the first FDA cleared and CE marked integrated leukemia and lymphoma immunophenotyping system.
Proper citation: Beckman Coulter Navios EX flow cytometer (RRID:SCR_023797) Copy
https://mass-spec.stanford.edu/instruments
Agilent 6495C triple quadrupole LC/MS system increases capacity and sensitivity for targeted quantitation applications. Used to investigate more diverse and biologically relevant groups of targeted peptides, small molecules and metabolites in single experiment without compromising sensitivity, quantitative accuracy, or linearity.
Proper citation: Agilent 6495 Triple Quadrupole LC/MS (RRID:SCR_023937) Copy
https://www.ambulatory-monitoring.com/pvt-192-psychomotor-vigilance-monitor
System includes PVT-192 monitor and REACT software. Used for reaction time testing for long-term, large-scale testing of vigilance, effects of sleep deprivation, and drug effects. Used for PVT test wherever measures of performance or sleepiness effects are needed.
Proper citation: Psychomotor Vigilance Task system (RRID:SCR_024213) Copy
https://www.eneuro.org/content/10/8/ENEURO.0212-23.2023
Simple, lightweight, and low cost customizable multielectrode array for Local Field Potential recordings. Used to collect LFP data from different brain regions simultaneously in rats. Can be modified to record single unit and multiunit activity in addition to LFP activity using both wired and wireless neural data acquisition systems.
Proper citation: Customizable Multielectrode Array (RRID:SCR_024551) Copy
https://github.com/EwellNeuroLab?tab=repositories
Low cost platform for multianimal chronic Local Field Potential video monitoring with Graphical User Interface for seizure detection and behavioral scoring. Enables chronic monitoring of several animals simultaneously, synchronizes bilateral local field potential and video streams in real time, and parses recorded data into manageable file sizes. Hardware solution leverages Intan and Open Ephys acquisition systems and software solution is implemented in Bonsai. Data are synchronized and parsed in Bonsai, allowing for flexibility and scalability of up to 128 channels per animal. The use of Intan adapter board for LFP video recordings allows compatibility with large variety of recording devices. Custom made electrodes and cables were components for the chronic LFP recordings. Used as acquisition system for long term video neurophysiology recordings.
Proper citation: LFP Monitoring (RRID:SCR_024428) Copy
https://docplayer.net/37250096-Fei-philips-cm120-tem.html
Transmission electron microscope with maximum acceleration voltage of 120 kv.Microscope primarily used for sample screening.
Proper citation: Philips/FEI CM120 BioTwin Transmission Electron Microscope (RRID:SCR_024709) Copy
https://www.emerson.com/en-us/catalog/branson-sfx250
Branson Sonifier ultrasonic cell disruptor / homogenizers are versatile laboratory units suitable for broad range of liquid processing applications. Digital sonifier to disrupt cells, bacteria, spores, or tissue. Ideal for initiating and accelerating chemical, biochemical, and physical reactions, and for degassing liquids. Used to prepare emulsion to 0.01 micron, homogenize immiscible liquids, polymerize some materials, and depolymerize others.
Proper citation: Branson Digital Sonifier SFX250 (RRID:SCR_024710) Copy
https://edspace.american.edu/openbehavior/project/attys/
Portal related to biomedical signals.Provides wearable data acquisition device with special focus on biomedical signals such as heart activity (ECG), muscle activity (EMG) and brain activity (EEG).Open source high precision bluetooth data acquisition device.
Proper citation: Attys project (RRID:SCR_021461) Copy
https://edspace.american.edu/openbehavior/project/autonomouse/
Project related to self initiated conditioning and behavior tracking in mice. Provides automated system that can track large numbers (over 25) of socially housed mice through implanted RFID chips on mice. With RFID trackers and other analyses, behavior of mice can be tracked as they train and are subsequently tested on (or self-initiate testing in) odor discrimination task over months with thousands of trials performed every day.
Proper citation: AutonoMouse project (RRID:SCR_021462) Copy
https://edspace.american.edu/openbehavior/project/autoreward2/
Project related to detection and rewarding rodents in modified T-maze task. System designed to detect and reward rodents in modified T maze provided by Ruhr University Bochum, Germany scientists.
Proper citation: Autoreward2 project (RRID:SCR_021460) Copy
https://edspace.american.edu/openbehavior/project/bpm-biosignals/
Portal as educational resource regarding construction and implementation of bioamplifiers as well as interpretation of biosignals.
Proper citation: BPM Biosignals project (RRID:SCR_021459) Copy
https://edspace.american.edu/openbehavior/project/automated-mouse-homecage-two-bottle-choice-test/
Project related to assessing preferences by mice among fluids in their homecages.Provided system includes homecage fitted apparatus for automated, photobeam based detection of licks in two bottle choice task. Used for automated mouse homecage two bottle choice test.
Proper citation: Automated mouse homecage two bottle choice test project (RRID:SCR_021457) Copy
https://edspace.american.edu/openbehavior/project/closed-loop-system/
Portal includes system for combined behavioral tracking, electrophysiology, and closed loop stimulation provided by University of Oslo scientists.Integrates Bonsai and Open Ephys with multiple modules.Provides guide for setting up this system.
Proper citation: Closed Loop System project (RRID:SCR_021475) Copy
https://edspace.american.edu/openbehavior/project/usv-detector/
Project related to ultrasonic vocalizations detection. Provides device designed for automatic detection of 50kHz ultrasonic vocalizations.
Proper citation: Ultrasonic Vocalizations Detector project (RRID:SCR_021471) Copy
Project related to function of cerebral cortex. Included model system for studying cortical function is provided by UC Berkeley scientists. System includes lickometer which employs infrared beam and sensor to minimize electrical noise artifacts during neurophysiology experiments and can be easily mounted in micromanipulator for precise and repeatable positioning.Open source lickometer was designed in conjunction with open source water delivery system.Together, these provide basic hardware for DIY behavioral assay and reward system for mice.
Proper citation: Feldman Lab Lickometer project (RRID:SCR_021469) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the NIF Resources search. From here you can search through a compilation of resources used by NIF and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that NIF has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on NIF then you can log in from here to get additional features in NIF such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into NIF you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within NIF that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.